    <ArticleTitle>Multi-Objective Safe Energy Management in Smart Buildings Using LSTM-Based Load Forecasting and Soft Actor-Critic Reinforcement Learning</ArticleTitle>
    <VernacularTitle>Multi-Objective Safe Energy Management in Smart Buildings Using LSTM-Based Load Forecasting and Soft Actor-Critic Reinforcement Learning</VernacularTitle>
    <FirstPage>1</FirstPage>
    <LastPage>23</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName></FirstName>
        <LastName></LastName>
        <Affiliation></Affiliation>
      </Author>
      <Author>
        <FirstName></FirstName>
        <LastName></LastName>
        <Affiliation></Affiliation>
      </Author>
      <Author>
        <FirstName></FirstName>
        <LastName></LastName>
        <Affiliation></Affiliation>
      </Author>
      <Author>
        <FirstName></FirstName>
        <LastName></LastName>
        <Affiliation></Affiliation>
      </Author>
      <Author>
        <FirstName></FirstName>
        <LastName></LastName>
        <Affiliation></Affiliation>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <History>
      <PubDate PubStatus="received">
        <Year>2025</Year>
        <Month>09</Month>
        <Day>08</Day>
      </PubDate>
    </History>
    <Abstract>&lt;p&gt;This study aimed to develop and evaluate an integrated LSTM–SAC–Safety Layer framework for predictive, multi-objective, and constraint-aware energy management in smart buildings, with simultaneous consideration of energy cost, peak demand, renewable-energy utilization, thermal comfort, and operational safety. A quantitative computational and experimental design was employed using real-world residential energy-consumption data from the Pecan Street Dataport, comprising 1,185 household identifiers and measurements recorded at 15-minute intervals throughout 2023. A stacked Long Short-Term Memory (LSTM) network was developed for short-term load forecasting, and its predictions were incorporated into the state space of a continuous-action Soft Actor–Critic (SAC) reinforcement-learning agent. A Safety Layer projected generated actions onto the feasible operating region before execution. Performance was evaluated over an independent 55-day test period under four scenarios: conventional rule-based control, standard SAC, LSTM–SAC without the Safety Layer, and the complete LSTM–SAC–Safety framework. Daily energy costs were additionally subjected to paired-samples t tests and Wilcoxon signed-rank tests. Inferential analysis demonstrated that the proposed LSTM–SAC–Safety framework produced statistically significant improvements in daily energy-cost performance compared with the competing reinforcement-learning configurations. The comparison between the proposed framework and LSTM–SAC yielded t = 4.82, p &amp;lt; .001, while the proposed framework also differed significantly from standard SAC (p &amp;lt; .001). The Wilcoxon signed-rank analysis corroborated the parametric findings, indicating that the observed superiority was not attributable to random variation across the 55 test days and remained statistically significant at the 99% confidence level. Integrating short-term LSTM forecasting with continuous SAC decision-making and an explicit Safety Layer provides a statistically supported and operationally reliable approach to smart-building energy management, enabling predictive control while maintaining physical feasibility and balancing economic, environmental, and occupant-comfort objectives.&lt;/p&gt;</Abstract>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Home Energy Management System (HEMS)</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Deep Reinforcement Learning</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Soft Actor–Critic (SAC)</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Long Short</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Term Memory (LSTM)</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Safety Layer</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Load Forecasting</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Smart Buildings</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Energy Optimization</Param>
      </Object>
    </ObjectList>
    <ArchiveCopySource DocType="pdf">https://journaldtai.com/index.php/jdtai/article/download/337/303</ArchiveCopySource>